Anaesthesia & intensive care medicine
Volume 11, Issue 4 , Pages 136-139, April 2010

The anaesthetic machine

Geraint Briggs FRCA is a Consultant Anaesthetist and College Tutor at the University Hospital of South Manchester, UK. Conflicts of interest: none declared

Sophie A Kimber Craig FRCA is a Registrar in Anaesthesia, currently based at Central Manchester Foundation Trust in Manchester, UK. Conflicts of interest: none declared

Abstract 

In 1917, Dr H Edmund G Boyle developed his continuous-flow anaesthesia machine, the design of which is the forerunner of all modern anaesthetic machines. This has undergone significant changes to increase the efficiency of anaesthesia and patient safety. Gases (oxygen, nitrous oxide and air) arrive at the machine via the hospital's piped medical gases and vacuum system via colour-coded tubing. Cylinders attached to the back of the machine must be present to provide a back-up supply of gases. The gases pass through pressure-regulating valves into the ‘back bar’ of the machine. From there, gas flow rate is set using a needle valve that regulates flow into the rotameter. Rotameters are fixed pressure, variable orifice flowmeters which are accurate to within ±2.5%. Modern anaesthetic machines may have electronic gas mixers rather than conventional rotameters. The gases pass through a vaporizer where anaesthetic is added to the fresh gas flow. This mixture is delivered, via the common gas outlet, to a patient breathing circuit, usually a ‘circle system’. This circulates gases and vapours and contains a carbon dioxide absorber to stop patients re-breathing carbon dioxide. Waste gases are scavenged. Monitoring, ventilators and suction apparatus are all incorporated into the machine.

Keywords: Anaesthetic machine, electronic gas mixing, gas, pressure-relief valve, rotameter, scavenging

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1472-0299(09)00323-3

doi:10.1016/j.mpaic.2009.12.015

Anaesthesia & intensive care medicine
Volume 11, Issue 4 , Pages 136-139, April 2010