Anaesthesia & intensive care medicine
Volume 8, Issue 8 , Pages 331-336, August 2007

Peripartum and intrapartum assessment of the fetus

Kim Hinshaw, MB, BS, FRCOG, is Consultant in Obstetrics and Gynaecology at Sunderland Royal Hospital, Sunderland, UK

Aarti Ullal, MB, BS, MRCOG, is Specialist Registrar in Obstetrics and Gynaecology at Sunderland Royal Hospital, Sunderland, UK

Abstract 

Intrapartum fetal surveillance is mandatory in every labour. Although structured intermittent auscultation is useful in low-risk labour, continuous electronic fetal heart rate monitoring (CEFM) is the main method used in medium- and high-risk clinical situations. Fetal heart rate patterns are a surrogate marker of the acid–base status of the fetus. However, widespread use of CEFM during the past 30 years has not resulted in a significant decrease in the incidence of cerebral palsy or neonatal encephalopathy. This is due to a combination of factors. Very few cases of cerebral palsy arise from known causes and beyond that an even smaller number are related to intrapartum asphyxia. CEFM is technically easy to introduce but interpretation is subjective and difficult to reproduce and standardize. Lack of uniformity in the interpretation of cardiotocograph (CTG) traces is well recognized. Training of staff and the use of computerized analysis can improve reliability in interpretation. Systematic clinical approaches to CTG interpretation are described in this article. In most cases, CEFM should be used as a screening test with the addition of fetal scalp blood sampling to confirm fetal acid–base balance. This will reduce the increased rates of operative intervention associated with CEFM. Recent research has focussed on analysis of the ST segment of the fetal ECG as an adjunct to CEFM. It is useful clinically and is associated with improved obstetric and neonatal outcomes. Fetal oxygen saturation monitoring with pulse oximetry techniques may also be useful in the clinical setting.

Keywords: CEFM, fetal ECG, fetal ST analysis, intrapartum fetal monitoring

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1472-0299(07)00145-2

doi:10.1016/j.mpaic.2007.06.004

Anaesthesia & intensive care medicine
Volume 8, Issue 8 , Pages 331-336, August 2007